With DC current measurement. Functions: voltmeter, ammeter, ohmmeter, capacitance meter, frequency meter, duty cycle meter, thermocouple, continuity test, diode test, NCV, phase detector

Voltmeter, ammeter, ohmmeter, capacitance meter, frequency meter, duty cycle meter, thermocouple
Basic functions of the measuring instrument
CAT III 600V
Equipment overvoltage protection classification
-40...+1832
Operating temperature range: limit temperature values at which no additional errors occur in electrical measuring devices
Availability

Product ID 82969
Brand Ermenrich
Warranty 5 years
EAN 5905555017488
Package size (LxWxH) 9.1x4.7x2 in
Shipping Weight 1 lb
Description

Using the Ermenrich Ping MK50 digital clamp meter, you can diagnose electrical equipment and measure the characteristics of electrical circuits. Both AC and DC currents are measured without breaking the circuit, and the device also works as a voltmeter, ohmmeter, thermocouple and duty cycle, frequency, and capacitance meter. Wide functionality, high measurement accuracy, and ease of operation make the Ermenrich Ping MK50 digital clamp meter an excellent choice for performing professional electrician tasks and maintaining the functionality of household electrical appliances and electrical wiring.

All of the measurements are carried out using the True RMS method, i.e. true root mean square value, which increases accuracy. When measuring DC current, you can use the DCA Zero function to compensate for residual magnetization. The device is intelligent, i.e., it can detect and measure the incoming signal in fully automatic mode: The Smart function works for continuity, voltage, and resistance measurements.

The continuity function is used for diagnostics; with its help, the electrical circuit is checked for continuity, and open and short circuits are detected. A separate test function is used to determine diode faults. Clamp meters can also work as a hazardous voltage detector: The NCV function is needed to find hidden wiring and electrical outlets. There is a phase detector.

The device is compact, great for working in hard-to-access places, and it has a built-in flashlight. Powered by batteries.

Key features:

  • Measures AC and DC current
  • Additional measuring functions: ohmmeter, voltmeter, capacitance meter, frequency meter, duty cycle meter, thermocouple
  • Smart function: automatic operation for continuity, resistance, and voltage measurement modes
  • NCV (hazardous voltage detection), continuity test (circuit continuity detection), diode testing, phase detector function
  • Data Hold function and minimums/maximums memory to simplify work with the measurement results
  • Built-in flashlight for working in dark rooms

The kit includes:

  • Clamp meter
  • Probes
  • Pouch
  • User manual and warranty card
specifications
Product ID 82969
Brand Ermenrich
Warranty 5 years
EAN 5905555017488
Package size (LxWxH) 9.1x4.7x2 in
Shipping Weight 1 lb
Selection of the measuring limit automatic
Basic functions voltmeter, ammeter, ohmmeter, capacitance meter, frequency meter, duty cycle meter, thermocouple
DC voltage measuring limit 600mV/6V/60V/600V: error ±(0.5%+5)
AC voltage measuring limit 600mV/6V/60V/600V: error ±(0.8%+5)
DC current measuring limit 60/600A: error ±(2.5%+5)
AC current measuring limit 60/600A: error ± (2.5%+5)
Resistance measuring limit 600Ω/6kΩ/60kΩ/600kΩ/6MΩ/60MΩ: error ±(1.0%+5)
Capacity measuring limit 6nF/60nF/600nF/6μF/60μF/600μF/6mF/60mF: error ±(4.0%+5)
Frequency measurement limits 100Hz/1000Hz/10kHz/100kHz/1MHz/10MHz: error ±(1.0%+3)
Duty cycle measurement range 1–99%: error ±(3.0%+3)
Wire mapping
Diodes test
Non-contact voltage detection (NCV)
True RMS
Hold function
Limit value function (Min/Max)
DCA Zero
Automatic recognition function (Smart) + (only for DC and AC voltage, resistance and continuity)
Phase detector (Live)
Overvoltage category CAT III 600V
Display counts 6000
Display backlight
Graphic scale
Flash light
Safety standards EN61010-1,-2-030; EN61010-2-033; EN61326-1
Operating temperature range, °F -40...+1832
Continuity test +, combined with resistance measurement mode (600Ω)
Power supply 3 AAA batteries (not included)
Low battery status indicator