MAGUS Bio 270T Biological Microscope
Magnification: 40–1000x. Trinocular microscope head, coded revolving nosepiece, plan achromatic objectives, 3W LED illuminator, intelligent lighting control system
Product ID | 83481 |
Brand | MAGUS |
Warranty | 5 years |
EAN | 5905555019475 |
Package size (LxWxH) | 29.9x18.9x20.1 in |
Shipping Weight | 39.2 lb |
Research grade microscope. Designed for observing transparent and translucent biological samples, such as smears and cross sections in transmitted light using the brightfield method. The installation of additional accessories will allow for darkfield, phase-contrast, fluorescence, and polarization methods.
The coded revolving nosepiece maintains a comfortable brightness level when switching objectives. Intelligent control of microscope lighting increases the comfort and speed of the researcher’s work. Thanks to the “smart” functions, there is no need to bother with the settings; the user’s attention is completely focused on solving their tasks.
Microscope head
Trinocular head with infinity-corrected optics. Eyepiece tubes rotate 360°. The user can adjust the eye relief on the eyepiece to fit their height. The digital camera is mounted in the trinocular tube. The beam splitting is 50/50.
The base kit includes 10x/22mm eyepieces with diopter adjustment and a long eye relief for working with glasses.
Revolving nosepiece and objectives
The coded revolver for 5 objectives is oriented toward the interior: The user can see the objective inserted into the optical path, and the space above the stage is free. An additional objective can also be installed in the free slot in order to achieve extra magnification. The parfocal distance is 60mm.
Above the revolver, there is a slot with a plug for installing the analyzer.
Maintaining comfortable brightness levels when switching magnifications
The objectives of different magnifications transmit light with different levels of intensity, and so each time you change objectives, the brightness of the light must be adjusted. In addition, brightness increases sharply when switching from a higher magnification objective to a lower magnification one. A sharp increase in brightness causes eye fatigue. MAGUS Bio 270T is equipped with intelligent brightness control. The optimal level of light brightness is automatically switched for each objective, thereby eliminating unexpected changes in brightness when changing magnification. This feature optimizes your workflow and reduces eye fatigue.
Focusing mechanism
With a large number of study objects, the operator constantly uses the fine focusing knob for their work. To reduce wrist strain, the microscope uses a responsive mechanism with smooth travel. The fine focusing knob has special grooves for your fingers. Fine-tuning the focus is effortless, and the right hand does not get tired.
The coarse and fine focusing knobs are coaxial and located low. The researcher can place their hands on the table and take a comfortable position in front of the microscope.
The coarse focus lock knob helps you quickly adjust the microscope after changing the subject of study. The knob is located on the left side of the microscope on the same axis as the focusing mechanism.
The ring on the right side adjusts the tension of the coarse focusing travel. The user adjusts the comfortable tension for work.
Stage
To ensure the ergonomic operation of the stage, it does not have an X-axis positioning rack. The belt-driven mechanism allows for the smooth movement of the specimen. The specimen holder is secured with two screws and can be easily removed during manual scanning.
The long stage control handle ensures user comfort while working: The hand rests on the table without strain.
Condenser
The Abbe condenser is height-adjustable and can be centered. Mounting type: dovetail.
The condenser ring adjusts the iris aperture diaphragm. The condenser body has an aperture marking, and the ring has an indicator marker. To achieve the contrast on each objective, it is recommended to rotate the ring so that the index marker matches the aperture marking of the objective being used.
Illumination
The transmitted light illuminator contains a 3W LED. The microscope illuminator has the function of adjusting the color temperature in the range from 3000 to 7000K. The user selects a color temperature that is comfortable for the eyes and easily changes it with one button when, for example, examining an object requires a change in light.
The LED has a lifespan of 50,000 hours.
Köhler illumination in transmitted light
The light source is located in the base at the back of the microscope, and the light is directed to the collector using a mirror. The image contrast is regulated by the aperture diaphragm of the condenser, and the illuminated field area is regulated by the field diaphragm of the collector.
The Köhler illumination improves the image quality of the observed sample: Each objective achieves maximum resolution, the field of view is illuminated evenly without darkening at the edges. The object of study is in sharp focus, and the image artifacts are removed.
LCD status screen
The LCD screen on the base of the microscope displays the objective magnification, brightness, and color temperature of the light source as well as operating mode (“sleep”, “eco”).
Using the screen and the relevant knob, the microscope user adjusts the brightness, selects the color temperature, locks the brightness adjustment, and sets the sleep mode and auto-off timer.
Ergonomic design
Physical discomfort causes fatigue and reduces productivity. The ergonomic design of the microscope plays an important role in everyday scientific research.
MAGUS Bio 270T provides user comfort during work.
By rotating the microscope head, the user selects a point of view height so as not to strain their back and neck.
Focusing knobs are located at the bottom of the body. The user does not strain their hands. Thanks to the smooth movement of the mechanism, the user can effortlessly focus on the object.
The microscope is operated with minimal hand movement since the long stage control handle and fine focusing knob are located in the same working area.
The microscope is equipped with a special carrying handle.
The design for the hidden placement of the power adapter and power cord improves the workplace esthetic and safety of carrying the microscope as well as simplifies storage of the device.
Accessories
There is a line of accessories designed for this microscope.
Optional objectives provide additional magnification.
The eyepieces extend the magnification range of the microscope. Optional eyepieces help you maximize the potential of the objective you use most often.
The phase contrast device, reflected light illuminator, dark field condensers, and polarization device extend contrast techniques and allow the examination of objects invisible in brightfield.
A digital camera outputs the microscope image to a monitor, store files, and software takes real-time measurements of specimens.
A calibration slide is used to measure objects, and it can be combined with the eyepiece with a scale or with the camera software.
Key features:
- Observations of transparent and translucent samples in brightfield in transmitted light
- The trinocular head with a vertical tube for installing a digital camera and height adjustment to adjust to the observer; light beam splitting 50/50
- Coded revolving nosepiece: The brightness of the light source is set automatically depending on the selected objective
- Transmitted light illuminator is energy-saving 3W LED with a lifetime of up to 50,000 hours
- Transmitted light Köhler illumination, centered and height-adjustable condenser with objective aperture markings
- Smart lighting control system: automatic brightness selection, dimming lock, timer auto-off, LCD operating status screen
- Stage without an X-axis positioning rack and with a long control handle for convenient operation
- Ergonomic stand with a carrying handle and the hidden placement of the power cord and power adapter
- Wide range of compatible optional accessories
The kit includes:
- Stand with built-in power supply, transmitted light source, focusing mechanism, stage, condenser mount, and revolving nosepiece
- Abbe condenser
- Trinocular head
- Plan achromatic infinity-corrected objective: 4x/0.10, parfocal height 60mm
- Plan achromatic infinity-corrected objective: 10x/0.25, parfocal height 60mm
- Plan achromatic infinity-corrected objective: 40x/0.65, parfocal height 60mm
- Plan achromatic infinity-corrected objective: 100x/1.25 oil (spring-loaded), parfocal height 60mm
- Eyepiece 10x/22 mm with long eye relief and diopter adjustment (2 pcs.)
- Eyepiece eyecup (2 pcs.)
- Light filter
- C-mount camera adapter
- Microscope power adapter and power cord
- Dust cover
- User manual and warranty card
Available on request:
- 10x/22mm eyepiece with scale
- 10x/22mm eyepiece with reticle
- 10x/22mm eyepiece with crosshairs
- 12.5x/17.5mm eyepiece (2 pcs.)
- 15x/16mm eyepiece (2 pcs.)
- 20x/12mm eyepiece (2 pcs.)
- Plan achromatic infinity-corrected objective: 20x/0.40, parfocal height 60mm
- Phase contrast device: phase contrast condenser, auxiliary centering telescope, set of phase objectives
- Darkfield condenser NA 0.7–0.9
- Darkfield immersion condenser NA 1.3–1.26
- Reflected light illuminator
- Polarization device
- Digital camera
- Calibration slide
- Monitor
Product ID | 83481 |
Brand | MAGUS |
Warranty | 5 years |
EAN | 5905555019475 |
Package size (LxWxH) | 29.9x18.9x20.1 in |
Shipping Weight | 39.2 lb |
Type | biological, light/optical |
Head | trinocular |
Nozzle | with 50/50 distribution of the luminous flux, Gemel head (Siedentopf, 360° rotation) |
Head inclination angle | 30 ° |
Magnification, x | 40 — 1000 |
Magnification, x (optional) | 40–1250/1500/2000 |
Eyepiece tube diameter, in | 1.2 |
Eyepieces | 10x/22, larga distancia de acomodación ocular. (*opcional: 10x/22 con escala de medición, 10x/22 con retícula, 10x/22 con cruz filar, 12,5x/17,5, 15x/16, 20x/12) |
Objectives | plan achromatic, infinity corrected: 4x/0.10; 10x/0.25; 40x/0.65; 100xs/1.25 oil (*optional: 20x/0.40); parfocal height 60mm |
Revolving nosepiece | 5 objectives, coded |
Working distance, mm | 30 (4x); 10.2 (10x); 1.5 (40x); 0.2 (100xs) |
Interpupillary distance, in | 1.9 — 3.1 |
Stage, mm | 235x150 |
Stage moving range, mm | 78/54 |
Stage features | two-axis mechanical stage, without a positioning rack |
Eyepiece diopter adjustment, diopters | ±5D on each eyepiece |
Eyepiece diopter adjustment | ✓ |
Condenser | Abbe condenser, N.A. 0.9, center-adjustable, height-adjustable, adjustable diaphragm, dovetail mount |
Diaphragm | adjustable aperture diaphragm, adjustable iris field diaphragm |
Focus | coaxial, coarse (32mm, 28mm/circle, with a lock knob and tension adjusting knob) and fine (0.001mm) |
Illumination | LED |
Brightness adjustment | ✓ |
Power supply | 100–240V, 50/60Hz (US type plug adapter is not included), AC network, the AC/DC power adapter is located in a special socket on the back of the stand |
Light source type | 3W LED, with color temperature adjustment (3000–7000K) |
Light filters | yes |
Operating temperature range, °F | 41...+95 |
Additional | automatic brightness adjustment when switching objectives, status display on LCD screen, sleep mode, eco mode |
Ability to connect additional equipment | phase contrast device (condenser and objectives), darkfield condenser (dry or oil), polarization devices (polarizer and analyzer), reflected light illuminator |
User level | experienced users, professionals |
Assembly and installation difficulty level | complicated |
Application | laboratory/medical |
Illumination location | lower |
Research method | bright field |
Pouch/case/bag in set | dust cover |