Lifetime Warranty See details
The price is valid only for the online store and may differ from the prices in retail stores.

With a camera. Magnification: 40–1000x. Trinocular head, plan achromatic and plan fluorite objectives, reflected light sources – 4 LEDs 5W of different wavelengths, transmitted light source – LED 3W, Köhler illumination in reflected and transmitted light

Trinocular
The microscope head is a core element of the microscope that you look through to see a magnified sample
Laboratory/medical
Application and use of the microscope
Availability

Product ID 83018
Brand MAGUS
Warranty 5 years
EAN 5905555018188
Package size (LxWxH) 17.7x11.8x37.8 cm
Shipping Weight 33.3 kg
Description

The MAGUS Lum 400L Fluorescence Microscope can be used for two microscopy techniques: fluorescence in reflected light and brightfield in transmitted light. When equipped with additional accessories, you can use the microscope to conduct research in polarized light as well as use darkfield and phase contrast techniques. The microscope can be used for research and laboratory diagnostics in the fields of medicine, pharmacology, forensics, biotechnology, veterinary medicine, etc.

Digital camera

The MAGUS CLM10 digital camera is designed for use in fluorescence and darkfield microscopy techniques. The camera is equipped with a 2.3MP sensor and produces realistic images at a resolution of 1920х1200px. It is recommended for 40x, 60x, and 100x objectives. When observing with medium magnification objectives, the camera will show finer details. Video is recorded at 120fps at maximum resolution. Videos are smooth, with soft and subtle transitions between frames. The movement of the object is displayed in real time with no delays. The camera makes it easy to work with objects that are moving and is suitable for classroom demonstrations. The camera is equipped with a USB3.0 interface. The data transfer speed is 10 times faster than USB2.0 cameras. The high-speed camera is recommended for professional laboratories, research, or university training.

Optics

The trinocular head includes two eyepiece tubes for observations and a trinocular tube for mounting a digital camera (not included). For comfortable longer observations, the eyepiece tubes can be adjusted to match the height of the observer, as they rotate 360°. They are 30° inclined.

The 5 objectives revolving nosepiece is oriented toward the interior – the user can see the objective inserted into the optical path. It comes with four infinity plan achromatic objectives: three for brightfield and one for fluorescence technique (fluo). One slot is left free when all objectives are installed in the revolving nosepiece. It is used for adjusting the position of the reflected light illuminator. You can also install an optional objective to get extra magnification.

Illumination

The reflected light – four 5W LEDs. Each LED has in a specific waveband: blue (B), green (G), violet (V), and ultraviolet (UV). To choose the working LED, you have to rotate the ring. The advantage of LED illumination is that LEDs get bright quickly and turn off quickly, making it easy to switch from brightfield to fluorescence and back again. LEDs do not heat up, they do not need a heat sink, and they have a lifetime of 50,000 hours without replacement. LED-based fluorescence is an easy to maintain and safe microscopy technique and, therefore, it is recommended for use at schools and universities.

The transmitted light is produced by a 3W LED. It also has a lifespan of 50,000 hours. The illumination system also includes a condenser. The condenser has a slot for a darkfield slider or a phase contrast slider. A slider is an easy and quick way to change the microscopy technique without changing the condenser.

For both transmitted and reflected light, you can set up Köhler illumination. The object of study is in sharp focus, and the image artifacts are removed. There is no darkening at the edges and the resolution limit can be reached at each objective.

Stage and focusing mechanism

The microscope stage is equipped with a removable specimen holder, which can be removed for manual scanning. The table does not have a positioning rack. Therefore, it requires less space for work. A black stage plate can be installed on the stage to eliminate stray light from the transmitted light source when observing in reflected light.

Coaxial coarse and fine focusing knobs are located at the base of the microscope on both sides. Coarse focusing has a lock knob and tension adjustment.

Accessories

The MAGUS Lum 400L microscope has a wide range of compatible accessories that can be used to expand its capabilities. It includes eyepieces, objectives, darkfield, polarized light and phase contrast devices as well as digital cameras and calibration slides.

Key features of the microscope:

  • Study of samples in reflected light using the fluorescence microscopy technique and in transmitted light using the brightfield microscopy technique.
  • Infinity plan achromatic objectives: three brightfield objectives, one fluo objective
  • Trinocular head, 360° rotatable barrels; a trinocular tube for mounting a digital camera
  • Four reflected light LEDs operating at different wavelengths: blue (B), green (G), violet (V) and ultraviolet (UV)
  • Transmitted light 3W LED, Köhler transmitted and reflected light illumination
  • Stage without a positioning rack, removable specimen holder
  • Wide range of accessories, including darkfield, polarized light and phase contrast devices

Key features of the camera:

  • For fluorescence and darkfield microscopy with 40x, 60x, and 100x objectives
  • 2.3MP resolution for getting detailed images at high magnification; low noise level, low-power dissipation
  • 120fps for observing moving objects, recording video, and moving the sample without jerkiness or delays
  • Global shutter for fast signal readout from the sensor, increased image brightness, and no false optical effects when observing moving objects
  • SONY Exmor monochrome CMOS backlit sensor provides low noise level and high light sensitivity even in low-light conditions. You will get clearer, brighter, and more color-saturated images.
  • USB3.0 interface for fast, smooth data transfer
  • Software with photo, video recording, editing, external display functions, linear and angular measurements

The kit includes:

  • MAGUS CLM10 Digital Camera (digital camera, USB cable, installation CD with drivers and software, user manual and warranty card)
  • Base with a power input, transmitted light source and condenser, focusing mechanism, stage, and revolving nosepiece
  • Reflected light illuminator
  • Lamphouse with LEDs
  • Trinocular head
  • Infinity plan achromatic objective: PL 4x/0.10 WD 19.8mm
  • Infinity plan achromatic objective: PL 10x/0.25 WD 5.0mm
  • Infinity plan achromatic objective, fluo: PL FL 40x/0.85 (spring-loaded) WD 0.42mm
  • Infinity plan achromatic objective, fluo: PL 100x/1.25 (spring-loaded, oil) WD 0.36mm
  • Eyepiece 10x/22mm with long eye relief (2 pcs.)
  • UV shield
  • C-mount adapter 1x
  • Hex key wrench
  • Reflected-light LEDs power supply
  • Power cord
  • Reflected light illuminator power cord
  • Dust cover
  • User manual and warranty card

Available on request:

  • 10x/22mm eyepiece with a scale
  • 12.5x/14mm eyepiece (2 pcs.)
  • 15x/15mm eyepiece (2 pcs.)
  • 20x/12mm eyepiece (2 pcs.)
  • 25x/9mm eyepiece (2 pcs.)
  • Infinity plan achromatic objective, fluo: PL FL 10x/0.35WD 2.37mm
  • Infinity plan achromatic objective: PL 60x/0.80 ∞/0.17 WD 0.46mm
  • Phase contrast device
  • Darkfield condenser
  • Immersion darkfield condenser
  • Darkfield slider
  • Polarization device
  • Calibration slide
specifications
Product ID 83018
Brand MAGUS
Warranty 5 years
EAN 5905555018188
Package size (LxWxH) 17.7x11.8x37.8 cm
Shipping Weight 33.3 kg
Microscope specifications
Type biological, light/optical, digital
Head trinocular
Nozzle Gemel head (Siedentopf, 360° rotation)
Head inclination angle 30 °
Eyepiece tube diameter, in 1.2
Eyepieces 10х/22mm, eye relief: 10mm (*optional: 10x/22mm with scale, 12.5x/14; 15x/15; 20x/12; 25x/9)
Objectives infinity plan achromatic and fluo objectives: PL 4x/0.10, PL 10x/0.25, PL FL 40x/0.85, PL 100x/1.25 (oil); parfocal distance 45mm (*optional: PL FL 10x/0.35, PL 60x/0.80 ∞/0.17)
Revolving nosepiece for 5 objectives
Working distance, mm 19.8 (4x); 5.0 (10x); 0.42 (FL 40x); 0.36 (100x); 2.37 (FL 10х); 0.46 (60х)
Interpupillary distance, in 1.9 — 3
Stage, mm 180x150
Stage moving range, mm 75/50
Stage features two-axis mechanical stage, without a positioning rack
Condenser Abbe condenser, N.A. 1.25, center-adjustable, height-adjustable, adjustable aperture diaphragm, a slot for a darkfield slider and phase contrast slider, dovetail mount
Diaphragm adjustable aperture diaphragm, adjustable iris field diaphragm
Focus coaxial, coarse focusing (21mm, 39.8mm/circle, with a lock knob and tension adjusting knob) and fine focusing (0.002mm)
Illumination LED, fluorescent
Brightness adjustment
Power supply 85–265V, 50/60Hz
Light source type reflected light: 4 LEDs of different wavelengths, 5W; transmitted light: 3W LED
Light filters yes
Ability to connect additional equipment phase contrast device (condenser and objectives), darkfield condenser (dry or oil), polarization devices (polarizer and analyzer), darkfield slider
User level experienced users, professionals
Assembly and installation difficulty level complicated
Fluorescent module filters: ultraviolet (UV), violet (V), blue (B), green (G)
Fluorescence filter: filter type, excitation wavelength/dichroic mirror/emission wavelength ultraviolet (UV), 320–380nm/420nm/435nm; violet (V), 380–415 nm/460 nm/475nm; blue (B), 410–490nm/505nm/515nm; green (G), 475–550nm/580nm/595nm
Application laboratory/medical
Illumination location dual
Research method bright field, fluorescence
Pouch/case/bag in set dust cover
Camera specifications
Sensor SONY Exmor CMOS
Color/monochrome monochrome
Megapixels 2.3
Maximum resolution, pix 1920х1200
Sensor size 1/1.2" (11.25x7.03 mm)
Pixel size, μm 5.86x5.86
Light sensitivity 1016mV with 1/30s
Signal/noise ratio 0.15mV at 1/30s
Exposure time 0.244ms–2s
Video recording
Video recording yes
Frame rate, fps at resolution 120@1920x1200
ADC digit capacity (bit) 8/12 (selectable)
Place of installation trinocular tube, eyepiece tube instead of an eyepiece
Image format *.jpg, *.bmp, *.png, *.tif
Video format output: *.wmv, *.avi, *.h264 (Windows 8 and later), *h265 (Windows 10 and later)
Spectral range, nm 380–650 (with IR filter and anti-reflective filter)
Shutter type Global shutter
White balance manual, automatic
Exposure control manual, automatic
Software features image size, brightness, exposure time
Software MAGUS View
Output USB 3.0, 5Gb/s
System requirements Windows 8/10/11 (32bit and 64bit), Mac OS X, Linux, up to 2.8GHz Intel Core 2 or higher, minimum 2GB RAM, USB3.0 port, CD-ROM, 17" or larger display
Mount type C-mount
Body CNC aluminum alloy
Camera power supply DC, 5V, from computer USB port; a 12V, 3A adapter for Peltier element
Camera operating temperature range, °F -10...+50
Operating humidity range, % 30 — 80
Questions and Answers
Submit your question
Your name *
Email *
Your question/comment *