Lifetime Warranty See details
The price is valid only for the online store and may differ from the prices in retail stores.

Magnification: 100–400x. Trinocular head, plan achromatic objectives, 5W LED transmitted light and reflected light illumination, Köhler illumination

Trinocular
The microscope head is a core element of the microscope that you look through to see a magnified sample
100–400 basic configuration (*optional: 40–500/600/800/1000)
How much the size of a sample increases when you observe it through a microscope
Laboratory/medical
Application and use of the microscope
Availability

Product ID 82909
Brand MAGUS
Warranty 5 years
EAN 5905555018232
Package size (LxWxH) 15x24x32.3 in
Shipping Weight 52.9 lb
Description

The MAGUS Lum V500L is an inverted microscope for fluorescence microscopy in the reflected light and brightfield and phase contrast microscopy in the transmitted light. DAPI, FITC, and TRITC fluorochrome filters are used for fluorescence microscopy. The inverted design allows you to study samples in laboratory ware such as petri dishes, flasks, etc. The height of the lab ware can be 55mm or 165mm when the stand is tilted. The optics are designed for lab ware with a bottom thickness of 1.2mm. The microscope is ideal for research and routine laboratory work and it can be used for educational purposes.

Optics

Two options for mounting a digital camera and monitor: The trinocular tube is for mounting a monitor (not included), and the side port on the body is for mounting a digital camera (not included). There is beam splitting: 100:0/0:100 (on the body) and 80:20 (trinocular head). The 45° eyepiece tube inclination angle allows for observation with maximum comfort. When assembling the microscope, the user can rotate the eyepiece tubes 180°.

The set includes six plan achromatic objectives: three of them for brightfield and fluorescence microscopy, and another three for phase-contrast microscopy. They are infinity-corrected and have a long working distance. The revolving nosepiece has six slots for mounting objectives. The revolving nosepiece is located under the stage on a stand.

Illumination

The fluorescence excitation source is a 5W LED with 50,000 hours of lifetime without replacement. There are three excitation filters: DAPI, FITC, and TRITC fluorochrome filters. LED illumination is more energy efficient and easier to maintain than mercury illumination, which is why it is recommended for use in universities. LED illumination provides color consistency. The LEDs turn on and off quickly and do not overheat during long hours of operation.

The source of the transmitted light is also a 5W LED. It is bright enough for brightfield and phase contrast microscopy techniques with each objective.

Both reflected and transmitted illumination can be adjusted according to the Köhler method. It allows you to reach the maximum resolution limit for each objective lens and get a clear, sharp image without artifacts or darkening at the edges.

The microscope is equipped with a phase-contrast condenser: Three slots are used for phase objectives with magnifications of 10x, 20x, and 40x, and the fourth slot is for brightfield microscopy. Phase rings can be centered. You can switch between the microscopy techniques by rotating a dial.

Stage and focusing mechanism

The fixed stage is equipped with a mechanical attachment for moving laboratory ware and three cup holders of different sizes. The lab ware can be moved in two mutually perpendicular directions in the horizontal plane. The microscope has a coarse and fine focusing mechanism. The coarse focusing mechanism has a lock knob and tension adjustment. The knobs are ergonomically designed to allow the user to maintain a relaxed posture while working.

Accessories

The microscope can be equipped with additional eyepieces, calibration slides, or a digital camera from the MAGUS line of accessories.

Key features:

  • Inverted design for observing samples in lab ware with a bottom thickness of 1.2mm and samples of up to 55mm height in as well as up to 165mm height if the stand is tilted up
  • Microscopy techniques: fluorescence (reflected light), brightfield and phase-contrast (transmitted light)
  • Köhler illumination setup for transmitted and reflected light; long-lasting 5W LEDs without replacement as light sources
  • There are three excitation filters: DAPI, FITC, and TRITC fluorochrome filters
  • Phase-contrast condenser for quick and convenient switching between the microscopy techniques
  • Trinocular head; two options to mount a camera or monitor: the 100:0/0:100 beam splitting (on the body), 80:20 beam splitting (on the head)

The kit includes:

  • Base with a power input, reflected light illuminator, transmitted light source, condenser, focusing mechanism, stage, and revolving nosepiece
  • Trinocular head
  • Infinity plan achromatic objective: PLL 10x/0.25 phase WD 4.3mm
  • Infinity plan achromatic objective: PLL 20х/0.40 WD 8.0mm
  • Infinity plan achromatic objective: PLL 40х/0.60 WD 3.5mm
  • Infinity plan achromatic objective: PLL 10x/0.25 PHP2 WD 4.3mm
  • Infinity plan achromatic objective: PLL 20x/0.40 PHP2 WD 8.0mm
  • Infinity plan achromatic objective: PLL 40x/0.60 PHP2 WD 3.5mm
  • Eyepiece 10x/22mm with long eye relief (2 pcs.)
  • UV shield
  • C-mount adapter 1x
  • Hex key wrench
  • Power cord
  • Dust cover
  • User manual and warranty card

Available on request:

  • 10x/22mm eyepiece with a scale
  • 12.5x/14mm eyepiece (2 pcs.)
  • 15x/15mm eyepiece (2 pcs.)
  • 20x/12mm eyepiece (2 pcs.)
  • 25x/9mm eyepiece (2 pcs.)
  • Digital camera
  • Calibration slide
specifications
Product ID 82909
Brand MAGUS
Warranty 5 years
EAN 5905555018232
Package size (LxWxH) 15x24x32.3 in
Shipping Weight 52.9 lb
Type biological, light/optical
Head trinocular
Nozzle Siedentopf, rotatable 180°
Magnification, x 100–400 basic configuration (*optional: 40–500/600/800/1000)
Eyepiece tube diameter, in 1.2
Eyepieces 10х/22mm, eye relief: 10mm (*optional: 10x/22mm with scale, 12.5x/14; 15x/15; 20x/12; 25x/9)
Objectives infinity plan achromatic: PLL 10x/0.25/4.3; PLL 20x/0.40/8.0; PLL 40x/0.60/3.5; phase: PLL 10x/0,25/4,3 PHP2; PLL 20x/0.40/8.0 PHP2; PLL 40x/0.60/3.5 PHP2; parfocal distance: 45mm
Revolving nosepiece for 6 objectives
Working distance, mm 4.3 (10х); 8.0 (20x); 3.5 (40x)
Interpupillary distance, in 1.9 — 3
Stage, mm 227x208
Stage moving range, mm 77/134.5
Stage features fixed, with mechanical attachment and glass plates Ø118mm; Ø118mm; cup holders: 86x129.5mm, Ø87.5mm; 34x77.5mm, Ø68.5mm; 57x82mm, Ø60mm
Condenser NA 0.6, working distance: 55mm; phase contrast turret; with locking screws
Diaphragm aperture iris diaphragm
Focus coaxial coarse and fine focusing knobs located on both sides
Illumination fluorescent, halogen
Brightness adjustment
Power supply AC network, 85–265V, 50/60Hz
Light source type reflected light: 5W LED; transmitted light: 5W LED
Light filters yes
Operating temperature range, °F 41...+95
Special features phase contrast condenser (turret) with a free slot and phase annuli plates for 10x, 20x and 40x objectives; centering auxiliary microscope
User level experienced users, professionals
Assembly and installation difficulty level complicated
Fluorescent module filters: ultraviolet (UV), violet (V), blue (B), green (G)
Fluorescence filter: filter type, excitation wavelength/dichroic mirror/emission wavelength ultraviolet (UV), 320–380nm/425 nm/435 nm; violet (V), 380–415nm/455nm/475nm; blue (B), 450–490nm/505nm/515nm; green (G), 495–555nm/585nm/595nm
Application laboratory/medical
Illumination location dual
Research method bright field, fluorescence, phase-contrast microscopy
Pouch/case/bag in set dust cover
Questions and Answers
Submit your question
Your name *
Email *
Your question/comment *